Journal Mobile Options
Table of Contents
Vol. 18, No. 1, 1992
Issue release date: 1992
Add to my selection Citation Download
Pediatr Neurosurg 1992;18:24–33
(DOI:10.1159/000120638)
Original Paper

Craniovertebral Abnormalities in Down’s Syndrome

Menezes A.H. · Ryken T.C.
Division of Neurological Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA Pediatr Neurosurg 1992;18:24–33 (DOI:10.1159/000120638)

Abstract

The ligamentous laxity associated with atlantoaxial subluxation has been assumed as a normal occurrence in 15–20% of Down’s syndrome patients. The occipitoatlantoaxial instability that accompanies this entity has been poorly recognized. The medical records and radiographic findings of 18 symptomatic patients with Down’s syndrome and cervicomedullary compromise were reviewed (1979–1991). All patients were evaluated prospectively under protocol for abnormalities of the cranial vertebral junction. There were 11 males and 7 females (age 3–42). ‘Fixed’ atlantoaxial luxation was seen in 8 (5 developed precipitous onset of cervical medullary compression). Occipitoatlantoaxial instability was present in 9 and associated rotary luxation in 9. The average predental space was 8 mm in the neutral position in 18 individuals. Two adolescents had previously undergone atlantoaxial dorsal fusion with subsequent progressive basilar invagination due to unrecognized occipitoat-lantal instability. An os odontoideum was seen in 3 patients. Irreducible invagination in 2 was treated with anterior decompression followed by dorsal occipital cervical fixation. The occipital cervical fixation was utilized in 10 individuals. Atlantoaxial dorsal fusion was made in 7 and 2 patients with acute rotary luxation of C1 and C2 were treated with immobilization. Halo immobilization in two individuals following a dorsal occipital cervical fixation produced an anterior fusion at the cranial vertebral complex indicating active vertebral ligamentous pathology. The review focuses on increased incidence of occiput cervical instability in the spectrum of craniovertebral junction abnormalities associated with Down’s syndrome. A large percentage has an odontoid ossicle probably as a result of repeated minor trauma. The results of surgical stabilization have been shown to be excellent.

 goto top of outline Author Contacts

Arnold H. Menezes, MD, Division of Neurological Surgery, University of Iowa Hospitals and Clinics, Iowa City, IA 52242 (USA)


 goto top of outline Article Information

Number of Print Pages : 10


 goto top of outline Publication Details

Pediatric Neurosurgery

Vol. 18, No. 1, Year 1992 (Cover Date: 1992)

Journal Editor: Frim D.M. (Chicago, Ill.)
ISSN: 1016–2291 (Print), eISSN: 1423–0305 (Online)

For additional information: http://www.karger.com/PNE


Copyright / Drug Dosage

Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher or, in the case of photocopying, direct payment of a specified fee to the Copyright Clearance Center.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in goverment regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.