Case Report

Deep Brain Stimulation Inactivity Can Produce Unexpected High Electrode Impedances when Reactivated, Leading to a False Conclusion of Wire Fracture

Jaggi J.L. · Baltuch G.H.

Author affiliations

Center for Functional and Restorative Neurosurgery, University of Pennsylvania, Philadelphia, Pa., USA

Related Articles for ""

Stereotact Funct Neurosurg 2005;83:187–189

Do you have an account?

Login Information





Contact Information










I have read the Karger Terms and Conditions and agree.



Login Information





Contact Information










I have read the Karger Terms and Conditions and agree.



To view the fulltext, please log in

To view the pdf, please log in

Buy

  • FullText & PDF
  • Unlimited re-access via MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

CHF 38.00 *
EUR 35.00 *
USD 39.00 *

Select

KAB

Buy a Karger Article Bundle (KAB) and profit from a discount!

If you would like to redeem your KAB credit, please log in.


Save over 20% compared to the individual article price.
Learn more

Rent/Cloud

  • Rent for 48h to view
  • Buy Cloud Access for unlimited viewing via different devices
  • Synchronizing in the ReadCube Cloud
  • Printing and saving restrictions apply

Rental: USD 8.50
Cloud: USD 20.00


Select

Subscribe

  • Access to all articles of the subscribed year(s) guaranteed for 5 years
  • Unlimited re-access via Subscriber Login or MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

Subcription rates


Select

* The final prices may differ from the prices shown due to specifics of VAT rules.

Article / Publication Details

First-Page Preview
Abstract of Case Report

Published online: April 06, 2006
Issue release date: April 2006

Number of Print Pages: 3
Number of Figures: 0
Number of Tables: 0

ISSN: 1011-6125 (Print)
eISSN: 1423-0372 (Online)

For additional information: http://www.karger.com/SFN

Abstract

Two months after bilateral DBS surgery in a patient with PD, the stimulator had to be removed temporarily due to an infection. After successful antibiotic treatment, a new stimulator and extension wire were reimplanted 2 months later. Intraoperative testing of the replacement device yielded unusually high electrode impedances and low currents on one lead across all four contacts. Since the results did not change on repeated measurements, a lead fracture was suspected. Visual inspection of the exposed hardware, however, did not reveal any obvious defects. It was then decided to activate the lead for a prolonged time with significant currents. Subsequent impedance measurements yielded normal values and after the patient awoke from anesthesia, good symptom control was again achieved. It is advisable if a lead fracture is suspected under similar circumstances to ‘condition’ the electrode with high currents. Failure to do so could lead to a false conclusion of a lead fracture and unnecessary stereotactic surgery to replace it.

© 2005 S. Karger AG, Basel


Article / Publication Details

First-Page Preview
Abstract of Case Report

Published online: April 06, 2006
Issue release date: April 2006

Number of Print Pages: 3
Number of Figures: 0
Number of Tables: 0

ISSN: 1011-6125 (Print)
eISSN: 1423-0372 (Online)

For additional information: http://www.karger.com/SFN


Copyright / Drug Dosage / Disclaimer

Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher or, in the case of photocopying, direct payment of a specified fee to the Copyright Clearance Center.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.