European Surgical Research
Original Paper
Favorable Tissue Effects of Quantum Molecular Resonance Device (Vesalius®) Compared with Standard ElectrocauteryA Novel Paradigm in Lung Surgery
Schiavon M.a · Calabrese F.b · Nicotra S.a · Marulli G.a · Pozzato G.c · Giacometti C.b · Valente M.b · Rea F.a
aDepartment of Cardiac, Thoracic and Vascular Sciences, Thoracic Surgery Branch and bDepartment of Pathology, University of Padova, Medical School, and cTELEA Electronic Engineering, Quinto Vicentino, Padova, Italy
|
|
Log in to MyKarger to check if you already have access to this content.
KAB
Buy a Karger Article Bundle (KAB) and profit from a discount!
If you would like to redeem your KAB credit, please log in.
Save over 20% compared to the individual article price.
Article / Publication Details
Received: November 04, 2006
Accepted: February 15, 2007
Published online: April 13, 2007
Issue release date: June 2007
Number of Print Pages: 7
Number of Figures: 5
Number of Tables: 0
ISSN: 0014-312X (Print)
eISSN: 1421-9921 (Online)
For additional information: https://www.karger.com/ESR
Abstract
Background: Electrosurgical devices are largely employed in thoracic surgery but their use is burdened by extensive necrosis and second intention healing. Methods: A rat model of thoracotomy was performed on 46 adult male rats using a standard electrocautery or a new quantum molecular resonance (QMR) instrument called Vesalius®. Skin, muscle and lung specimens were obtained immediately and 2 weeks after surgery to evaluate acute and late effects. Results: Both in the short- and long-term study, Vesalius produced less severe tissue damage than that of standard electrocautery. Conclusions: The use of the QMR device may provide an alternative to gold-standard electrosurgical devices in thoracic surgery.
© 2007 S. Karger AG, Basel
Related Articles:
References
- Dixon AR, Watkin DF: Electrosurgical skin incision versus conventional scalpel: a prospective trial. J R Coll Surg Edinb 1990;35:299–301.
- Kalkwarf KL, Krejci RF, Shaw DH, et al: Histologic evaluation of gingival response to an electrosurgical blade. J Oral Maxillofac Surg 1987;45:671–674.
- Chinpairoj S, Feldman MD, Saunders JC, et al: A comparison of monopolar electrosurgery to a new multipolar electrosurgical system in a rat model. Laryngoscope 2001;111:213–217.
- Hambley R, Hebda PA, Abell E, et al: Wound healing of skin incisions produced by ultrasonically vibrating knife, scalpel, electrosurgery, and carbon dioxide laser. J Dermatol Surg Oncol 1988;14:1213–1217.
-
Pozzato G, Vignato G: Teoria della risonanza quantica molecolare nella realizzazione del bisturi elettronico ‘Vesalius’. Quintessence Int 2003;5/6:153–155.
- Yang GP, Lim IJ, Phan TT, et al: From scarless fetal wounds to keloids: molecular studies in wound healing. Wound Repair Regen 2003;11:411–418.
- Santini M, Vicidomini G, Baldi A, et al: Use of an electrothermal bipolar tissue sealing system in lung surgery. Eur J Cardiothorac Surg 2006;29:226–230.
- Tajiri M, Maehara T, Ishiwa N, et al: Evaluation of an ultrasonic cutting and coagulating system (harmonic scalpel) for performing a segmental and wedge resection of the lung. Kyobu Geka 1998;51:1116–1119.
- Wilson RP, Zagon IS, Larach DR, et al: Cardiovascular and respiratory effects of tiletamine-zolazepam. Pharmacol Biochem Behav 1993;44:1–8.
- Greene SA, Thurmon JC: Xylazine – a review of its pharmacology and use in veterinary medicine. J Vet Pharmacol Ther 1988;11:295–313.
- Epstein WL, Fukuyama K: Mechanisms of granulomatous inflammation. Immunol Ser 1989;46:687–721.
- Cakan A, Cagirici U, Cikirikcioglu M, et al: The histological effect of harmonic scalpel and electrocautery in lung resections. An experimental study in a rat model. J Cardiovasc Surg 2004;45:63–65.
- Schemmel M, Haefner HK, Selvaggi SM, et al: Comparison of the ultrasonic scalpel to CO2 laser and electrosurgery in terms of tissue injury and adhesion formation in a rabbit model. Fertil Steril 1997;67:382–386.
- Kalso E, Perttunen K, Kaasinen S: Pain after thoracic surgery. Acta Anaesthesiol Scand 1992;36:96–100.
- Boisseau N, Rabary O, Padovani B, et al: Improvement of ‘dynamic analgesia’ does not decrease atelectasis after thoracotomy. Br J Anaesth 2001;87:564–569.
- LoCicero J 3rd, Frederiksen JW, Hartz RS, et al: Pulmonary procedures assisted by optosurgical and electrosurgical devices: comparison of damage potential. Lasers Surg Med 1987;7:263–272.
- Buvanendran A, Kroin JS, Kerns JM, et al: Characterization of a new animal model for evaluation of persistent postthoracotomy pain. Anesth Analg 2004;99:1453–1460.
- Vore SJ, Wooden WA, Bradfield JF, et al: Comparative healing of surgical incisions created by a standard ‘bovie,’ the Utah Medical Epitome Electrode, and a Bard-Parker cold scalpel blade in a porcine model: a pilot study. Ann Plast Surg 2002;49:635–645.
Article / Publication Details
Received: November 04, 2006
Accepted: February 15, 2007
Published online: April 13, 2007
Issue release date: June 2007
Number of Print Pages: 7
Number of Figures: 5
Number of Tables: 0
ISSN: 0014-312X (Print)
eISSN: 1421-9921 (Online)
For additional information: https://www.karger.com/ESR
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

Get Permission