Respiration

Clinical Investigations

Variability of Exhaled Breath Condensate pH in Lung Transplant Recipients

Czebe K.a · Kullmann T.b · Csiszer E.a · Barat E.b · Horvath I.b · Antus B.a, b

Author affiliations

aDepartment of Pulmonology and bDepartment of Pathophysiology, National Koranyi Institute for TB and Pulmonology, Budapest, Hungary

Related Articles for ""

Respiration 2008;75:339–344

Log in to MyKarger to check if you already have access to this content.


Buy

  • FullText & PDF
  • Unlimited re-access via MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

CHF 38.00 *
EUR 35.00 *
USD 39.00 *

Select

KAB

Buy a Karger Article Bundle (KAB) and profit from a discount!


If you would like to redeem your KAB credit, please log in.


Save over 20% compared to the individual article price.

Learn more

Rent/Cloud

  • Rent for 48h to view
  • Buy Cloud Access for unlimited viewing via different devices
  • Synchronizing in the ReadCube Cloud
  • Printing and saving restrictions apply

Rental: USD 8.50
Cloud: USD 20.00

Select

Subscribe

  • Access to all articles of the subscribed year(s) guaranteed for 5 years
  • Unlimited re-access via Subscriber Login or MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

Subcription rates


Select
* The final prices may differ from the prices shown due to specifics of VAT rules.

Article / Publication Details

First-Page Preview
Abstract of Clinical Investigations

Received: June 05, 2007
Accepted: October 02, 2007
Published online: November 28, 2007
Issue release date: March 2008

Number of Print Pages: 6
Number of Figures: 2
Number of Tables: 1

ISSN: 0025-7931 (Print)
eISSN: 1423-0356 (Online)

For additional information: https://www.karger.com/RES

Abstract

Background: Measurement of pH in exhaled breath condensate (EBC) may represent a novel method for investigating airway pathology. Objectives: The aim of this longitudinal study was to assess the variability of EBC pH in stable lung transplant recipients (LTR). Methods: During routine clinical visits 74 EBC pH measurements were performed in 17 LTR. EBC pH was also measured in 19 healthy volunteers on four separate occasions. EBC pH was determined at standard CO2 partial pressure by a blood gas analyzer. Results: Mean EBC pH in clinically stable LTR and in controls was similar (6.38 ± 0.09 vs. 6.44 ± 0.16; p =nonsignificant). Coefficient of variation for pH in LTR and controls was 2.1 and 2.3%, respectively. The limits of agreement for between-visit variability determined by the Bland-Altman test in LTR and healthy volunteers were also comparable (–0.29 and 0.46 vs. –0.53 and 0.44). Conclusions: Our data suggest that the variability of EBC pH in stable LTR is relatively small, and it is similar to that in healthy nontransplant subjects.

© 2007 S. Karger AG, Basel




Related Articles:


References

  1. Horvath I, Hunt J, Barnes PJ, et al: Exhaled breath condensate: methodological recommendations and unresolved questions. Eur Respir J 2005;26:523–548.
  2. Vaughan J, Ngamtrakulpanit L, Pajewski TN, Turner R, Nguyen TA, Smith A, Urban P, Hom S, Gaston B, Hunt J: Exhaled breath condensate pH is a robust and reproducible assay of airway acidity. Eur Respir J 2003;22:889–894.
  3. Hunt JF, Fang K, Malik R, Snyder A, Malbotra N, Platta-Mills TA, Gaston B: Endogenous airway acidification. Implications for asthma pathophysiology. Am J Respir Crit Care Med 2000;161:694–699.
  4. Tate S, MacGregor G, Davis M, Innes JA, Greening AP: Airways in cystic fibrosis are acidified: detection by exhaled breath condensate. Thorax 2002;57:926–929.
  5. Kostikas K, Papatheodorou G, Ganas K, Psathakis K, Panagou P, Loukides S: pH in expired breath condensate of patients with inflammatory airway diseases. Am J Respir Crit Care Med 2002;165:1364–1370.
  6. Kullmann T, Barta I, Lazar Z, Szili B, Barat E, Valyon M, Kollai M, Horvath I: Exhaled breath condensate pH standardised for CO2 partial pressure. Eur Respir J 2007;29:496–501.
  7. Boehler A, Estenne M: Post-transplant bronchiolitis obliterans. Eur Respir J 2003;22:1007–1018.
  8. Dupont LJ, Dewandeleer Y, Vanaudenaerde BM, Van Raemdonck DE, Verleden GM: The pH of exhaled breath condensate of patients with allograft rejection after lung transplantation. Am J Transplant 2006;6:1486–1492.
  9. Zheng L, Walters EH, Ward C, Wang N, Orsida B, Whitford H, Williams TJ, Kotsimbos T, Snell GI: Airway neutrophilia in stable and bronchiolitis obliterans syndrome patients following lung transplantation. Thorax 2000;55:53–59.
  10. Estenne M, Maurer JR, Boehler A, Egan JJ, Frost A, Hertz M, Mallory GB, Snell GI, Yousem S: Bronchiolitis obliterans syndrome 2001: an update of the diagnostic criteria. J Heart Lung Transplant 2002;21:297–310.
  11. Antus B, Csiszer E, Czebe K, Horvath I: Pulmonary infections increase exhaled nitric oxide in lung transplant recipients: a longitudinal study. Clin Transplant 2005;19:377–382.
  12. Yousem SA, Berry GJ, Cagle PT, Chamberlain D, Husain AN, Hruban RH, Marchevsky A, Ohori NP, Ritter J, Stewart S, Tazelaar HD: Revision of the 1990 working formulation for the classification of pulmonary allograft rejection. Lung Rejection Study Group. J Heart Lung Transplant 1996;15:1–15.
  13. Vass G, Huszar E, Barat E, Valyon M, Kiss D, Penzes I, Augusztinovicz M, Horvath I: Comparison of nasal and oral inhalation during exhaled breath condensate collection. Am J Respir Crit Care Med 2003;167:850–855.
  14. Huszar E, Vass G, Vizi E, Csoma Z, Barat E, Molnar Vilagos G, Herjavecz I, Horvath I: Adenosine in exhaled breath condensate in healthy volunteers and in patients with asthma. Eur Respir J 2002;20:1393–1398.
  15. American Thoracic Society; European Respiratory Society: ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005. Am J Respir Crit Care Med 2005;171:912–930.
  16. Standardization of Spirometry, 1994 Update. American Thoracic Society. Am J Respir Crit Care Med 1995;152:1107–1136.
  17. Borrill Z, Starkey C, Vestbo J, Singh D: Reproducibility of exhaled breath condensate pH in chronic obstructive pulmonary disease. Eur Respir J 2005;25:269–274.
  18. Chladkova J, Krcmova I, Chladek J, Cap P, Micuda S, Hanzalkova Y: Validation of nitrite and nitrate measurements in exhaled breath condensate. Respiration 2006;73:173–179.
  19. van Beurden WJ, Dekhuijzen PN, Harff GA, Smeenk FW: Variability of exhaled hydrogen peroxide in stable COPD patients and matched healthy controls. Respiration 2002;69:211–216.
  20. Davidsson A, Naidu Sjosward K, Lundman L, Schmekel B: Quantitative assessment and repeatability of chlorine in exhaled breath condensate. Respiration 2005;72:529–536.
  21. Silkoff PE, Caramori M, Tremblay L, McClean P, Chaparro C, Kesten S, Hutcheon M, Slutsky AS, Zamel N, Keshavjee S: Exhaled nitric oxide in human lung transplantation. A noninvasive marker of acute rejection. Am J Respir Crit Care Med 1998;157:1822–1828.
  22. Fisher AJ, Gabbay E, Small T, Doig S, Dark JH, Corris PA: Cross sectional study of exhaled nitric oxide levels following lung transplantation. Thorax 1998;53:454–458.
  23. Verleden GM, Dupont LJ, Delcroix M, Van Raemdonck D, Vanhaecke J, Lerut T, Demedts M: Exhaled nitric oxide after lung transplantation: impact of the native lung. Eur Respir J 2003;21:429–432.
  24. Bloemen K, Lissens G, Desager K, Schoeters G: Determinants of variability of protein content, volume and pH of exhaled breath condensate. Respir Med 2007;101:1331–1337.
  25. Liu J, Thomas PS: Relationship between exhaled breath condensate volume and measurements of lung volumes. Respiration 2007;74:142–145.
  26. Kullmann T, Barta I, Horvath I: Effect of freezing on exhaled breath condensate pH. Respir Med 2007;101:2566.

Article / Publication Details

First-Page Preview
Abstract of Clinical Investigations

Received: June 05, 2007
Accepted: October 02, 2007
Published online: November 28, 2007
Issue release date: March 2008

Number of Print Pages: 6
Number of Figures: 2
Number of Tables: 1

ISSN: 0025-7931 (Print)
eISSN: 1423-0356 (Online)

For additional information: https://www.karger.com/RES


Copyright / Drug Dosage / Disclaimer

Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.