Background/Aims: The validity of fluorescence optodes for measurement of renal cortical tissue oxygen tension was tested by comparison with Clark electrodes. Methods: We varied renal blood flow and inspired O2 content in anaesthetized rabbits while simultaneously measuring cortical tissue oxygen tension. Results: Cortical oxygen tension varied with inspired O2 content. Fluorescence optode measurements were more tightly distributed than those from a Clark electrode. Cumulative frequency distributions for fluorescence optodes were shifted to the left of those for Clark electrodes. The slope of the relationship between oxygen tension in arterial blood and cortical tissue was less for the fluorescence optode than the Clark electrode. Cortical tissue oxygen tension measurements by these two methods were correlated (r2 = 0.32; p < 0.001), with no fixed bias but considerable proportional bias. Thus, the slope of the relationship between the two measurements was less than unity (0.57 [0.50–0.69]). Conclusion: Cortical oxygen tension values from fluorescence optodes are less variable but proportionally less than those from Clark electrodes. Theoretical considerations suggest that true interstitial oxygen tension lies somewhere between values provided by the two techniques. Nevertheless, the lesser variability of the fluorescence optode technique may aid detection of physiologically significant changes in intrarenal oxygenation.

1.
Severinghaus JW: First electrodes for blood PO2 and PCO2 determination. J Appl Physiol 2004;97:1599–1600.
2.
Whalen WJ, Riley J, Nair P: A microelectrode for measuring intracellular PO2. J Appl Physiol 1967;23:798–801.
3.
Tsai AG, Johnson PC, Intaglietta M: Oxygen gradients in the microcirculation. Physiol Rev 2003;83:933–963.
4.
O’Connor PM: Renal oxygen delivery: matching delivery to metabolic demand. Clin Exp Pharmacol Physiol 2006;33:961–967.
5.
Griffiths JR, Robinson SP: The OxyLite: a fibre-optic oxygen sensor. Br J Radiol 1999;72:627–630.
6.
O’Connor PM, Kett MM, Anderson WP, Evans RG: Renal medullary tissue oxygenation is dependent on both cortical and medullary blood flow. Am J Physiol Renal Physiol 2006;290:F688–F694.
7.
Whitehouse T, Stotz M, Taylor V, Stidwill R, Singer M: Tissue oxygen and hemodynamics in renal medulla, cortex, and corticomedullary junction during hemorrhage-reperfusion. Am J Physiol Renal Physiol 2006;291:F647–F653.
8.
O’Connor PM, Anderson WP, Kett MM, Evans RG: Renal preglomerular arterial-venous O2 shunting is a structural antioxidant defence mechanism of the renal cortex. Clin Exp Pharmacol Physiol 2006;33:637–641.
9.
Leong CL, Anderson WP, O’Connor PM, Evans RG: Evidence that renal arterial-venous oxygen shunting contributes to dynamic regulation of renal oxygenation. Am J Physiol Renal Physiol 2007;292:F1726–F1733.
10.
Eppel GA, Luff SE, Denton KM, Evans RG: Type 1 neuropeptide Y receptors and α1-adrenoceptors in the neural control of regional renal perfusion. Am J Physiol 2006;290:R331–R340.
11.
Young WK, Vojnovic B, Wardman P: Measurement of oxygen tension in tumours by time-resolved fluorescence. Br J Cancer Suppl 1996;27:S256–S259.
12.
Ludbrook J: Comparing methods of measurements. Clin Exp Pharmacol Physiol 1997;24:193–203.
13.
Ivanov KP, Sokolova IB, Vovenko EP: Oxygen transport in the rat brain cortex at normobaric hyperoxia. Eur J Appl Physiol Occup Physiol 1999;80:582–587.
14.
Schurek HJ, Jost U, Baumgartl H, Bertram H, Heckmann U: Evidence for a preglomerular oxygen diffusion shunt in rat renal cortex. Am J Physiol 1990;259:F910–F915.
15.
Welch WJ, Baumgartl H, Lubbers D, Wilcox CS: Nephron pO2 and renal oxygen usage in the hypertensive rat kidney. Kidney Int 2001;59:230–237.
16.
Duling BR, Berne RM: Longitudinal gradients in periarteriolar oxygen tension. A possible mechanism for the participation of oxygen in local regulation of blood flow. Circ Res 1970;27:669–678.
17.
Pittman RN: Influence of microvascular architecture on oxygen exchange in skeletal muscle. Microcirculation 1995;2:1–18.
18.
Pittman RN: Oxygen transport and exchange in the microcirculation. Microcirculation 2005;12:59–70.
19.
Ulfendahl HR: Distribution of red cells and plasma in rabbit and cat kidneys. Acta Physiol Scand 1962;56:42–60.
20.
Braun RD, Lanzen JL, Snyder SA, Dewhirst MW: Comparison of tumor and normal tissue oxygen tension measurements using OxyLite or microelectrodes in rodents. Am J Physiol Heart Circ Physiol 2001;280:H2533–H2544.
21.
Lubbers DW, Baumgartl H: Heterogeneities and profiles of oxygen pressure in brain and kidney as examples of the pO2 distribution in the living tissue. Kidney Int 1997;51:372–380.
22.
Welch WJ, Mendonca M, Aslam S, Wilcox CS: Roles of oxidative stress and AT1 receptors in renal hemodynamics and oxygenation in the postclipped 2K,1C kidney. Hypertension 2003;41:692–696.
23.
Baumgartl H, Leichtweiss HP, Lubbers DW, Weiss C, Huland H: The oxygen supply of the dog kidney: measurements of intrarenal pO2. Microvasc Res 1972;4:247–257.
24.
Schneiderman G, Goldstick TK: Oxygen electrode design criteria and performance characteristics: recessed cathode. J Appl Physiol 1978;45:145–154.
25.
Toma-Dasu I, Dasu A, Waites A, Denekamp J, Fowler JF: Theoretical simulation of oxygen tension measurement in the tissue using a microelectrode. II. Simulated measurements in tissues. Radiother Oncol 2002;64:109–118.
26.
James PE, Bacic G, Grinberg OY, Goda F, Dunn JF, Jackson SK, Swartz HM: Endotoxin-induced changes in intrarenal pO2, measured by in vivo electron paramagnetic resonance oximetry and magnetic resonance imaging. Free Radic Biol Med 1996;21:25–34.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.