Brain, Behavior and Evolution

Neural Prostheses

An in vitro Analysis of Metal Electrodes for Use in the Neural Environment

Johnson P.F. · Hench L.L.

Author affiliations

Department of Materials Science and Engineering, University of Florida, Gainesville, Fla.

Related Articles for ""

Brain Behav Evol 1977;14:23–45

Log in to MyKarger to check if you already have access to this content.


Buy

  • FullText & PDF
  • Unlimited re-access via MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

CHF 9.00 *
EUR 8.00 *
USD 9.00 *

Select

KAB

Buy a Karger Article Bundle (KAB) and profit from a discount!


If you would like to redeem your KAB credit, please log in.


Save over 20% compared to the individual article price.

Learn more

Rent/Cloud

  • Rent for 48h to view
  • Buy Cloud Access for unlimited viewing via different devices
  • Synchronizing in the ReadCube Cloud
  • Printing and saving restrictions apply

Rental: USD 8.50
Cloud: USD 20.00

Select

Subscribe

  • Access to all articles of the subscribed year(s) guaranteed for 5 years
  • Unlimited re-access via Subscriber Login or MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

Subcription rates


Select
* The final prices may differ from the prices shown due to specifics of VAT rules.

Article / Publication Details

First-Page Preview
Abstract of Neural Prostheses

Published online: April 03, 2008
Issue release date: 1977

Number of Print Pages: 23
Number of Figures: 0
Number of Tables: 0

ISSN: 0006-8977 (Print)
eISSN: 1421-9743 (Online)

For additional information: https://www.karger.com/BBE

Abstract

The results of evaluation of the corrosion response of Pt, Au, Rh, Ir, Pt-10% Ir and Pt-10% Rh electrodes subjected to bipolar current pulses of 0.1 and 1.0 A/geom. cm2 in a simulated neural environment are reported. The criteria for evaluation include the extent and morphology of material removal and corrosion product formation. The chemical changes on the electrode surface and in the test electrolyte are also evaluated. Modified potentiographic methods were developed which monitor interface conditions of the electrodes during chronic, long-term bi-phasic current passage. Under the test conditions established by the neural model, evaluation of the corrosion response of the candidate electrode materials shows that Rh was moderately damaged at 1.0 A/geom. cm2, while the remaining test electrodes were severely damaged at this current density. While Rh, Ir and Au exhibit corrosion resistance at 0.1 A/geom. cm2, damage to all of the test materials preclude their use in any long-term chronic neural prosthetic implant under the simulated stimulation parameters of the tests. The relative corrosion resistance of the test electrode materials is related to the adherence and coherence of the corrosion product produced on the electrode surface during the first few hundred hours of stimulation. Analysis of the voltage response of the electrodes to current passage provides a means of monitoring the nucleation and growth of the corrosion product.

© 1977 S. Karger AG, Basel




Related Articles:


Article / Publication Details

First-Page Preview
Abstract of Neural Prostheses

Published online: April 03, 2008
Issue release date: 1977

Number of Print Pages: 23
Number of Figures: 0
Number of Tables: 0

ISSN: 0006-8977 (Print)
eISSN: 1421-9743 (Online)

For additional information: https://www.karger.com/BBE


Copyright / Drug Dosage / Disclaimer

Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
TOP