Cochlear Implants and Hearing Preservation
Editor(s): Van de Heyning, P. (Antwerp)Kleine Punte, A. (Antwerp)
Surgery
Electric Acoustic Stimulation in Patients with Postlingual Severe High-Frequency Hearing Loss: Clinical ExperienceArnoldner C.a · Helbig S.b · Wagenblast J.b · Baumgartner W.-D.a · Hamzavi J.-S.a · Riss D.a · Gstoettner W.aaDepartment of Otorhinolaryngology, Medical University of Vienna, Vienna, Austria; bDepartment of Otorhinolaryngology, Johann Wolfgang Goethe University, Frankfurt/Main, Germany
|
|
Log in to MyKarger to check if you already have access to this content.
KAB
Buy a Karger Article Bundle (KAB) and profit from a discount!
If you would like to redeem your KAB credit, please log in.
Save over 20% compared to the individual article price.
Article / Publication Details
Published online: November 25, 2009
Cover Date: 2010
Number of Print Pages: 9
Number of Figures: 0
Number of Tables: 0
ISBN: 978-3-8055-9286-4 (Print)
eISBN: 978-3-8055-9287-1 (Online)
Abstract
Background/Aims: The aim of this study was to describe audiological outcomes and surgical considerations in electric acoustic stimulation for patients with severe to profound high-frequency hearing loss. Methods: In this latest series of patients in our center, all patients were supplied with the new (atraumatic) Flex EAS MED-EL electrode. Eleven patients (age 7.62–71.32 years) with profound high-frequency hearing loss were implanted with this electrode, which was designed to preserve residual hearing despite the intracochlear insertion of an electrode array. All patients were operated on by the same surgeon (W.G.). Results: The rate of complete or partial hearing preservation was 100% after a mean follow-up period of 7.85 months (range 0.95–15.65 months). Conclusion: This study proves that both refined surgical techniques and atraumatic electrodes are mandatory to preserve residual hearing after cochlear implantation. Flexible, thin, and free-fitting straight electrodes, such as the MED-EL Flex EAS electrode used in this study, seem to most accurately meet the requirements for hearing preservation in electric acoustic stimulation.
© 2010 S. Karger AG, Basel
Related Articles:
References
-
von Ilberg C, Kiefer J, Tillein J, Pfenningdorff T, Hartmann R, Stürzebecher E, Klinke R: Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. ORL J Otorhino-laryngol Relat Spec 1999;61:334-340
-
Kiefer J, Pok M, Adunka O, Stürzebecher E, Baumgartner W, Schmidt M, Tillein J, Ye Q, Gstoettner W: Combined electric and acoustic stimulation of the auditory system: results of a clinical study. Audiol Neurootol 2005;10:134-144
-
Turner CW, Reiss LA, Gantz BJ: Combined acoustic and electric hearing: preserving residual acoustic hearing. Hear Res 2008;242:164-171
-
Hodges AV, Schloffman J, Balkany T: Conservation of residual hearing with cochlear implantation. Am J Otol 1997;18:179-183
-
Gantz BJ, Turner C, Gfeller KE: Acoustic plus electric speech processing: preliminary results of a multicenter clinical trial of the Iowa/Nucleus Hybrid implant. Audiol Neurootol 2006;11:(Suppl 1)63-68
-
Fitzgerald MB, Sagi E, Jackson M, Sha-piro WH, Roland JT, Jr, Waltzman SB, Svirsky MA: Reimplantation of hybrid cochlear implant users with a full-length electrode after loss of residual hearing. Otol Neurotol 2008;29:168-173
-
Gstoettner W, Arnoldner C: Re: reimplantation of hybrid cochlear implant users with a full-length electrode after loss of residual hearing. Otol Neurotol 2008;29:881-882
-
Gstoettner WK, Helbig S, Maier N, Kiefer J, Radeloff A, Adunka OF: Ipsilateral electric acoustic stimulation of the auditory system: results of long-term hearing preservation. Audiol Neurootol 2006;11:(Suppl 1)49-56
-
Briggs RJ, Tykocinski M, Stidham K, Roberson JB: Cochleostomy site: implications for electrode placement and hearing preservation. Acta Otolaryngol 2005;125:870-876
-
Adunka OF, Radeloff A, Gstoettner WK, Pillsbury HC, Buchman CA: Scala tympani cochleostomy. 2. Topography and histology. Laryngoscope 2007;117:2195-2200
-
Tykocinski M, Cohen LT, Pyman BC, Roland T, Jr, Treaba C, Palamara J, Dahm MC, Shepherd RK, Xu J, Cowan RS, Cohen NL, Clark GM: Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays. Am J Otol 2000;21:205-211
-
Gstoettner WK, Adunka O, Franz P, Hamzavi J, Jr, Plenk H, Jr, Susani M, Baumgartner W, Kiefer J: Perimodiolar electrodes in cochlear implant surgery. Acta Otolaryngol 2001;121:216-219
-
Adunka O, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W: Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation. Laryngoscope 2004;114:1237-1241
-
Adunka O, Gstoettner W, Hambek M, Unkelbach MH, Radeloff A, Kiefer J: Preservation of basal inner ear structures in cochlear implantation. ORL J Otorhinolaryngol Relat Spec 2004;66:306-312
-
Adunka O, Unkelbach MH, Mack MG, Radeloff A, Gstoettner W: Predicting basal cochlear length for electric-acoustic stimulation. Arch Otolaryngol Head Neck Surg 2005;131:488-492
-
Adunka O, Kiefer J: Impact of electrode insertion depth on intracochlear trauma. Otolaryngol Head Neck Surg 2006;135:374-382
-
Choi CH, Oghalai JS: Predicting the effect of post-implant cochlear fibrosis on residual hearing. Hear Res 2005;205:193-200
-
Gantz BJ, Turner CW: Combining acoustic and electrical hearing. Laryngoscope 2003;113:1726-1730
-
Hochmair I, Arnold W, Nopp P, Jolly C, Müller J, Roland P: Deep electrode insertion in cochlear implants: apical morphology electrodes and speech perception results. Acta Otolaryngol 2003;123:612-617
-
Hamzavi J, Arnoldner C: Effect of deep insertion of the cochlear implant electrode array on pitch estimation and speech perception. Acta Otolaryngol 2006;126:1182-1187
-
Lenarz T, Stover T, Buechner A, Paasche G, Briggs R, Risi F, Pesch J, Battmer RD: Temporal bone results and hearing preservation with a new straight electrode. Audiol Neurootol 2006;11:(Suppl 1)34-41
-
Roland PS, Wright CG, Isaacson B: Cochlear implant electrode insertion: the round window revisited. Laryngoscope 2007;117:1397-1402
-
James CJ, Fraysse B, Deguine O, Lenarz T, Mawman D, Ramos A, Ramsden R, Sterkers O: Combined electroacoustic stimulation in conventional candidates for cochlear implantation. Audiol Neurootol 2006;11:(Suppl 1)57-62
-
Skarzynski H, Lorens A, Piotrowska A, Anderson I: Preservation of low frequency hearing in partial deafness cochlear implantation (PDCI) using the round window surgical approach. Acta Otolaryngol 2007;127:41-48
-
Garcia-Ibanez L, Macias AR, Morera C, Rodriguez MM, Szyfter W, Skarszynski H, Emamdjomeh H, Baumgartner WD: An evaluation of the preservation of residual hearing with the Nucleus Contour Advance electrode. Acta Otolaryngol 2008;27:1-14
Article / Publication Details
Published online: November 25, 2009
Cover Date: 2010
Number of Print Pages: 9
Number of Figures: 0
Number of Tables: 0
ISBN: 978-3-8055-9286-4 (Print)
eISBN: 978-3-8055-9287-1 (Online)
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

Get Permission