Ophthalmic Research

Original Paper

Dynamics of Macular Hole Closure in Gas-Filled Eyes within 24 h of Surgery Observed with Swept Source Optical Coherence Tomography

Kikushima W.a · Imai A.a · Toriyama Y.a · Hirano T.a · Murata T.a · Ishibashi T.b

Author affiliations

aDepartment of Ophthalmology, School of Medicine, Shinshu University, Matsumoto, and bDepartment of Ophthalmology, Faculty of Medicine, Kyushu University, Fukuoka, Japan

Related Articles for ""

Ophthalmic Res 2015;53:48-54

Log in to MyKarger to check if you already have access to this content.


Buy

  • FullText & PDF
  • Unlimited re-access via MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

CHF 38.00 *
EUR 35.00 *
USD 39.00 *

Select

KAB

Buy a Karger Article Bundle (KAB) and profit from a discount!


If you would like to redeem your KAB credit, please log in.


Save over 20% compared to the individual article price.

Learn more

Rent/Cloud

  • Rent for 48h to view
  • Buy Cloud Access for unlimited viewing via different devices
  • Synchronizing in the ReadCube Cloud
  • Printing and saving restrictions apply

Rental: USD 8.50
Cloud: USD 20.00

Select

Subscribe

  • Access to all articles of the subscribed year(s) guaranteed for 5 years
  • Unlimited re-access via Subscriber Login or MyKarger
  • Unrestricted printing, no saving restrictions for personal use
read more

Subcription rates


Select
* The final prices may differ from the prices shown due to specifics of VAT rules.

Article / Publication Details

First-Page Preview
Abstract of Original Paper

Received: July 08, 2014
Accepted: September 15, 2014
Published online: December 18, 2014
Issue release date: January 2015

Number of Print Pages: 7
Number of Figures: 3
Number of Tables: 1

ISSN: 0030-3747 (Print)
eISSN: 1423-0259 (Online)

For additional information: https://www.karger.com/ORE

Abstract

Background/Aims: To investigate the dynamics of macular hole (MH) closure in gas-filled eyes starting 20 min after vitrectomy using swept source optical coherence tomography (SS-OCT). Methods: Twenty consecutive eyes with MH underwent vitrectomy with internal limiting membrane peeling and gas tamponade. SS-OCT imaging was performed approximately 20 min after the operation, and then once a day, until MH closure was confirmed. The correlation between the base, top and minimum hole diameters and the duration required for MH closure was investigated. Results: MH closure in gas-filled eyes was confirmed in 1 eye on day 0, 10 eyes on day 1, 2 eyes on day 2, and 3 eyes on day 3, at which times face-down posturing was discontinued without MH recurrence. SS-OCT revealed a distinct closure pattern within the first 24 h postoperatively. MHs closing by day 1 had a significantly smaller minimum diameter (312.5 ± 105.2 µm) than holes closing on day 2 or later (510.8 ± 153.5 µm; p = 0.019). Conclusions: SS-OCT enables tomographic images of MH in gas-filled eyes immediately postoperatively, thus permitting early discontinuation of, or no necessity for, face-down positioning upon confirmation of MH closure.

© 2014 S. Karger AG, Basel




Related Articles:


References

  1. Vincent JM, Peyman GA, Ratnakaram R: Bilateral ulnar decubitus as a complication of macular hole surgery. Ophthalmic Surg Lasers Imaging 2003;34:485-486.
    External Resources
  2. Dhawahir-Scala FE, Maino A, Saha K, Mokashi AA, McLauchlan R, Charles S: To posture or not to posture after macular hole surgery. Retina 2008;28:60-65.
  3. Eckardt C, Eckert T, Eckardt U, Porkert U, Gesser C: Macular hole surgery with air tamponade and optical coherence tomography-based duration of face-down positioning. Retina 2008;28:1087-1096.
  4. Tranos PG, Peter NM, Nath R, Singh M, Dimitrakos S, Charteris D, Kon C: Macular hole surgery without prone positioning. Eye (Lond) 2007;21:802-806.
  5. Tornambe PE, Poliner LS, Grote K: Macular hole surgery without face-down positioning. A pilot study. Retina 1997;17:179-185.
  6. Lange CA, Membrey L, Ahmad N, Wickham L, Maclaren RE, Solebo L, Xing W, Bunce C, Ezra E, Charteris D, Aylward B, Yorston D, Gregor Z, Zambarakji H, Bainbridge JW: Pilot randomised controlled trial of face-down positioning following macular hole surgery. Eye (Lond) 2012;26:272-277.
  7. Tatham A, Banerjee S: Face-down posturing after macular hole surgery: a meta-analysis. Br J Ophthalmol 2010;94:626-631.
  8. Guillaubey A, Malvitte L, Lafontaine PO, Jay N, Hubert I, Bron A, Berrod JP, Creuzot-Garcher C: Comparison of face-down and seated position after idiopathic macular hole surgery: a randomized clinical trial. Am J Ophthalmol 2008;146:128-134.
  9. Tadayoni R, Gaudric A, Haouchine B, Massin P: Relationship between macular hole size and the potential benefit of internal limiting membrane peeling. Br J Ophthalmol 2006;90:1239-1241.
  10. Michalewska Z, Michalewski J, Nawrocki J: Swept-source OCT, wide-field simultaneous choroid, retina, and vitreous visualization. Retina Today September 2013, pp 50-56.
  11. Masuyama K, Yamakiri K, Arimura N, Sonoda Y, Doi N, Sakamoto T: Posturing time after macular hole surgery modified by optical coherence tomography images: a pilot study. Am J Ophthalmol 2009;147:481-488.
  12. Yamashita T, Yamashita T, Kawano H, Sonoda Y, Yamakiri K, Sakamoto T: Early imaging of macular hole closure: a diagnostic technique and its quality for gas-filled eyes with spectral domain optical coherence tomography. Ophthalmologica 2013;229:43-49.
  13. Sano M, Inoue M, Taniuchi S, Kunita D, Hiraoka T, Hirakata A: Ability to determine postoperative status of macular hole in gas-filled eyes by spectral-domain optical coherence tomography. Clin Experiment Ophthalmol 2011;39:885-892.
  14. Jumper JM, Gallemore RP, McCuen BW 2nd, Toth CA: Features of macular hole closure in the early postoperative period using optical coherence tomography. Retina 2000;20:232-237.
    External Resources
  15. Yamakiri K, Sakamoto T: Early diagnosis of macular hole closure of a gas-filled eye with Watzke-Allen slit beam test and spectral domain optical coherence tomography. Retina 2012;32:767-772.
  16. Kim NM, Park HJ, Koo GH, Lee JE, Oum BS: Photoreceptor layer assessed in tissue layer image using spectral-domain optical coherence tomography after surgical closure of macular hole. Retina 2011;31:1483-1492.
  17. Shah SP, Manjunath V, Rogers AH, Baumal CR, Reichel E, Duker JS: Optical coherence tomography-guided facedown positioning for macular hole surgery. Retina 2013;33:356-362.
  18. Gass JD: Reappraisal of biomicroscopic classification of stages of development of a macular hole. Am J Ophthalmol 1995;119:752-759.
  19. Ip MS, Baker BJ, Duker JS, Reichel E, Baumal CR, Gangnon R, Puliafito CA: Anatomical outcomes of surgery for idiopathic macular hole as determined by optical coherence tomography. Arch Ophthalmol 2002;120:29-35.
  20. Tadayoni R, Vicaut E, Devin F, Creuzot-Garcher C, Berrod JP, Le Mer Y, Korobelnik JF, Aout M, Massin P, Gaudric A: A randomized controlled trial of alleviated positioning after small macular hole surgery. Ophthalmology 2011;118:150-155.
  21. Yorston D, Siddiqui MA, Awan MA, Walker S, Bunce C, Bainbridge JW: Pilot randomised controlled trial of face-down posturing following phacovitrectomy for macular hole. Eye (Lond) 2012;26:267-271.
  22. Kang SW, Ahn K, Ham DI: Types of macular hole closure and their clinical implications. Br J Ophthalmol 2003;87:1015-1019.
  23. Grigoropoulos VG, Theodossiadis GP, Theodossiadis PG: Association of the preoperative photoreceptor layer defect as assessed by optical coherence tomography with the functional outcome after macular hole closure: a long follow-up study. Ophthalmologica 2011;225:47-54.
  24. Ullrich S, Haritoglou C, Gass C, Schaumberger M, Ulbig MW, Kampik A: Macular hole size as a prognostic factor in macular hole surgery. Br J Ophthalmol 2002;86:390-393.
  25. Ehlers JP, Xu D, Kaiser PK, Singh RP, Srivastava SK: Intrasurgical dynamics of macular hole surgery: an assessment of surgery-induced ultrastructural alterations with intraoperative optical coherence tomography. Retina 2014;34:213-221.
  26. Xu D, Yuan A, Kaiser PK, Srivastava SK, Singh RP, Sears JE, Martin DF, Ehlers JP: A novel segmentation algorithm for volumetric analysis of macular hole boundaries identified with optical coherence tomography. Invest Ophthalmol Vis Sci 2013;54:163-169.
  27. Rosa RH Jr, Glaser BM, de la Cruz Z, Green WR: Clinicopathologic correlation of an untreated macular hole and a macular hole treated by vitrectomy, transforming growth factor-beta 2, and gas tamponade. Am J Ophthalmol 1996;122:853-863.
  28. Hara S, Sakuraba T, Nakazawa M: Morphological changes of retinal pigment epithelial and glial cells at the site of experimental retinal holes. Graefes Arch Clin Exp Ophthalmol 2000;238:690-695.

Article / Publication Details

First-Page Preview
Abstract of Original Paper

Received: July 08, 2014
Accepted: September 15, 2014
Published online: December 18, 2014
Issue release date: January 2015

Number of Print Pages: 7
Number of Figures: 3
Number of Tables: 1

ISSN: 0030-3747 (Print)
eISSN: 1423-0259 (Online)

For additional information: https://www.karger.com/ORE


Copyright / Drug Dosage / Disclaimer

Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
TOP