Abstract
Iron deficiency is a common problem in patients on chronic HD. Earlier studies have shown significant blood loss per HD session. To identify whether the new more biocompatible high-flux or high-efficiency membranes are also responsible for significant blood loss during HD, we quantitated the amount of blood loss associated with 4 commonly used membranes (F-50, F-80, CA-210, and CT-190). The residual blood in each compartment of extracorporeal circuit was quantitated after total lysis of the red blood cells (RBC), hemoglobin assay, and calculation of the RBC volume using the patient’s hemoglobin and hematocrit concentrations just prior to the study. The average residual RBC volume in different membranes was 0.2–0.3 ml. The residual RBC volume in the dialysis lines (arterial or venous) was 0.1–0.2 ml and did not correlate with the residual RBC volume in the dialysis membranes. The residual RBC volume in the whole extracorporeal circuit (HD membrane, arterial and venous lines) ranged from 0.5 to 0.6 ml. It was significantly higher with F-50 vs. CA-210. The residual RBC volume in the dialysis membrane was significantly higher in the F-80 vs. CA-210 and CT-190 dialyzers. There was also significant difference in the residual RBC volume in the arterial lines of F-50 vs. CT-190, and F-50 vs. F-80 dialyzers. Conclusion: Our results demonstrate for the first time that the total RBC loss per HD session is minimal in chronic HD patients.
© 2001 S. Karger AG, Basel
Related Articles:
References
- Druke TB, Barany P, Cazzola M, Eschobach JW, Grutzmacher P, Kaltwasser JP, Macdougall IC, Pippard MJ, Shaldon S, van Wyck D: Management of iron deficiency in renal anemia: Guidelines for the optimal therapeutic approach in erythropoietin-treated patients. Clin Nephrol 1997;48:1–8.
- Lindsay RM, Burton JA, King P, Davidson JF, Boddy K. Kennedy AC: The measurement of dialyzer blood loss. Clin Nephrol 1973;1:24–28.
-
Evans DB, Clarkson EM, Curtis JR: Blood loss using the modified two-layer Kiil dialyser. Br Med J 1967;iv:651–653.
- Muth RG, Wells DE: Four new coil hemodialyzers: Comparison of dialysance ultrafiltration, and erythrocyte recovery. Arch Intern Med 1969;124:179–183.
- Will G, Lawson DH, King P, Boddy K, Linton AL: Blood loss in the Kolff twin-coil artificial kidney. Nephron 1970;7:331–338.
- Khayat MC, Laforet F, Bureau F, Thomas M, Dorsdowsky M: Plasma hemoglobin. Comparison between 2 methods of determination. Pathol Biol (Paris) 1989;37:236–240.
-
Murihead N, Bargman J, Burgess E, Jindall KK, Levin A, Nolin L, Parfrey P: Evidence-based recommendations for the clinical use of recombinant human erythropoietin. Am J Kidney Dis 1995;26:S1–S24.
- Madore F, Lowrie EG, Brugnara C, Lew NL, Lazarus JM, Bridges K, Owen WF: Anemia in hemodialysis patients: Variables affecting this outcome predictor. J Am Soc Nephrol 1997;8:1921–1929.
- Ismail N, Becker BN: An opportunity to intervene: Erythropoietin for the treatment of anemia in pre-dialysis patients. Nephrol Dial Transplant 1998;13:14–17.
- Greelings W, Morris RW, Brunner FP, Brynger H, Ehrich JH, Fassibinder W, Rizzoni G, Selwood NH, Tufveson G, Wing JA: Factors influencing anaemia in dialysis patients: A special survey by the EDTA-ERA registry. Nephrol Dial Transplant 1993;8:585–589.
- Carozzi S, Nasini MG, Santoni O, Triotta A, Sanna A: Recombinant human erythropoietin resistance in hemodialysis: Effects of paired filtration dialysis. ASAIO J 1997;43:M535–M538.
- Ifudu O, Dawood M, Friedman EA: Relative contribution of body iron status and uremia severity to anemia in patients with advanced chronic renal failure. Nephron 1997;77:315–318.
- Ahluwalia N, Skikne BS, Savin V, Chonko A: Markers of masked iron deficiency and effectiveness of EPO therapy in chronic renal failure. Am J Kidney Dis 1997;30:532–541.
- Rault R, Maganone M: The effect of parathyroidectomy on hematocrit and erythropoietin dose in patients on hemodialysis. ASAIO J 1996;42:M901–M903.
- Maekowitz GS, Kahn GA, Feingold RE, Coco M, Lynn RI: An evaluation of the effectiveness of oral ion therapy in the hemodialysis patients receiving recombinant human erythropoietin. Clin Nephrol 1997;48:34–40.
- Rosenblatt SG, Drake S, Fadem S, Welch R, Lifschitz MD: Gastrointestinal blood loss in patients with chronic renal failure. Am J Kidney Dis 1982;1:232–236.
- Dave PB, Romeu J, Antonelli A, Eiser AR: Gastrointestinal telangiectasias. Arch Intern Med 1984;144:1781–1783.
-
Wizemann V, Buddensiek P, De Booe J, Grebe S, Schutterle G: Gastrointestinal blood loss in patients undergoing maintenance dialysis. Kidney Int 1983;24:S218–S220.
- Lindsay RM, Prentice CR, Burton JA, Ferguson D, Kennedy AC: The role of the platelet-dialysis membranes interaction in the thrombous formation and blood loss during hemodialysis. Trans Am Soc Artif Intern Organs 1973;19:487–491.
- Salter MC, Crow MJ, Donaldson DR, Roberts TG, Rajah SM, Davidson AM: Prevention of platelet deposition and thrombus formation on hemodialysis membrane: A double-blind randomized trial of aspirin and dipyridamole. Artif Organs 1984;8:57–61.
- Cases A, Reverter JC, Escolar G, Sanz C, Sorribes J, Ordinas A: In vivo evaluation of platelet activation by different cellulosic membranes. Artif Organs 1997;21:330–334.
- Cheung AK, Faezi-Jenkin B, Leyoldt K: Effect of thrombosis on the complement activation and neutrophil degranulation during in vitro hemodialysis. J Am Soc Nephrol 1994;5:110–115.
-
Falkenhagen D, Brown GS: Clinical evaluation of three hemodialysis containing PMMA membranes of different surface area, with special attention to thrombogenicitiy. Nephrol Dial Transplant 1991;6(suppl 2):43–48.
Article / Publication Details
Published online: March 12, 2001
Issue release date: January – February
Number of Print Pages: 4
Number of Figures: 1
Number of Tables: 2
ISSN: 0250-8095 (Print)
eISSN: 1421-9670 (Online)
For additional information: https://www.karger.com/AJN
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

Get Permission