Ophthalmic Research
Research Article
Visual Outcomes after Small Incision Lenticule Extraction and Femtosecond Laser-Assisted LASIK for High MyopiaYang W.a · Liu S.b · Li M.c,d,e · Shen Y.c,d,e · Zhou X.c,d,eaDepartment of Ophthalmology and Optometry, Children’s Hospital of Fudan University, Shanghai, China
bJiangxi Research Institute of Ophthalmology and Visual Sciences, Department of Affiliated Eye Hospital of Nanchang University, Nanchang, China cDepartment of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China dNHC Key Laboratory of Myopia, Fudan University, Shanghai, China eShanghai Research Center of Ophthalmology and Optometry, Shanghai, China |
|
Log in to MyKarger to check if you already have access to this content.
KAB
Buy a Karger Article Bundle (KAB) and profit from a discount!
If you would like to redeem your KAB credit, please log in.
Save over 20% compared to the individual article price.
Article / Publication Details
Received: July 22, 2019
Accepted: October 22, 2019
Published online: December 05, 2019
Issue release date: July 2020
Number of Print Pages: 7
Number of Figures: 5
Number of Tables: 2
ISSN: 0030-3747 (Print)
eISSN: 1423-0259 (Online)
For additional information: https://www.karger.com/ORE
Abstract
Purpose: The aim of this study was to compare visual outcomes after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) for high myopia. Methods: In this prospective, comparative study, a total of 52 eyes of 34 consecutive highly myopic patients with spherical equivalent within the range of –8.00 to –10.00 diopters were recruited. Twenty-three eyes of 16 patients were in the FS-LASIK group and 29 eyes of 18 patients were in the SMILE group. Visual outcomes and wavefront aberrations were analyzed preoperatively and 6 months postoperatively. Results: At the postoperative 6-month visit, 96.6% in the SMILE group and 91.3% in the FS-LASIK group achieved unchanged or better corrected distance visual acuity (CDVA). As for uncorrected distance visual acuity (UDVA), 96.6% in the SMILE group and 95.7% in the FS-LASIK group achieved UDVA of 20/20 or better. As for wavefront aberrations, high-order aberrations (HOAs) and spherical aberrations increased significantly after surgery in both groups relative to corresponding preoperative values (p < 0.001), and vertical coma increased after SMILE (p < 0.001). No statistically significant differences in changes of HOAs (p =0.90), spherical aberrations (p = 0.07), horizontal coma (p = 0.56), coma (p =0.08), horizontal trefoil (p =0.19), vertical trefoil (p = 0.90), and trefoil (p = 0.45) were detected between the 2 groups, except for vertical coma (p < 0.01). Conclusions: SMILE is as effective as FS-LASIK in correcting high myopia, but attention should be paid to the induction of vertical coma in highly myopic patients following a SMILE procedure.
© 2019 S. Karger AG, Basel
Related Articles:
References
- Sekundo W, Gertnere J, Bertelmann T, Solomatin I. One-year refractive results, contrast sensitivity, high-order aberrations and complications after myopic small-incision lenticule extraction (ReLEx SMILE). Graefes Arch Clin Exp Ophthalmol. 2014 May;252(5):837–43.
- Vestergaard AH. Past and present of corneal refractive surgery: a retrospective study of long-term results after photorefractive keratectomy, and a prospective study of refractive lenticule extraction. Acta Ophthalmol. 2014 Aug;92(5):492–3.
- Lin F, Xu Y, Yang Y. Comparison of the visual results after SMILE and femtosecond laser-assisted LASIK for myopia. J Refract Surg. 2014 Apr;30(4):248–54.
- Ganesh S, Gupta R. Comparison of visual and refractive outcomes following femtosecond laser- assisted lasik with smile in patients with myopia or myopic astigmatism. J Refract Surg. 2014 Sep;30(9):590–6.
- Han T, Zheng K, Chen Y, Gao Y, He L, Zhou X. Four-year observation of predictability and stability of small incision lenticule extraction. BMC Ophthalmol. 2016 Aug;16(1):149.
- Qin B, Zhao J, Li M, Yao P, Zhou X. The comparison of visual outcomes, aberrations, and Bowman’s layer micro-distortions after femtosecond laser small-incision lenticule extraction (SMILE) for the correction of high and moderate myopia and myopic astigmatism. BMC Ophthalmol. 2019 Jun;19(1):138.
- Sánchez-González JM, Alonso-Aliste F. Visual and refractive outcomes of 100 small incision lenticule extractions (SMILE) in moderate and high myopia: a 24-month follow-up study. Graefes Arch Clin Exp Ophthalmol. 2019 Jul;257(7):1561–7.
- Yang X, Liu F, Liu M, Liu Q, Weng S, Lin H. 15-Month Visual Outcomes and Corneal Power Changes of SMILE in Treating High Myopia With Maximum Myopic Meridian Exceeding 10.00 D. J Refract Surg. 2019 Jan;35(1):31–9.
- Ağca A, Çakır İ, Tülü Aygün B, Yaşa D, Yıldırım Y, Yıldız BK, et al. Visual and Refractive Outcomes of Small-Incision Lenticule Extraction in High Myopia: 5-Year Results. J Ophthalmol. 2018 Oct;2018:5893126.
- Xia LK, Ma J, Liu HN, Shi C, Huang Q. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism. Int J Ophthalmol. 2018 Mar;11(3):470–7.
- Chen X, Guo L, Han T, Wu L, Wang X, Zhou X. Contralateral eye comparison of the long-term visual quality and stability between implantable collamer lens and laser refractive surgery for myopia. Acta Ophthalmol. 2019 May;97(3):e471–8.
- Harrer A, Hirnschall N, Tabernero J, Artal P, Draschl P, Maedel S, et al. Variability in angle κ and its influence on higher-order aberrations in pseudophakic eyes. J Cataract Refract Surg. 2017 Aug;43(8):1015–9.
- Gobbe M, Reinstein DZ, Archer TJ. LASIK-induced aberrations: comparing corneal and whole-eye measurements. Optom Vis Sci. 2015 Apr;92(4):447–55.
- Li M, Zhao J, Miao H, Shen Y, Sun L, Tian M, et al. Mild decentration measured by a Scheimpflug camera and its impact on visual quality following SMILE in the early learning curve. Invest Ophthalmol Vis Sci. 2014 May;55(6):3886–92.
- Li M, Zhou Z, Shen Y, Knorz MC, Gong L, Zhou X. Comparison of corneal sensation between small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK for myopia. J Refract Surg. 2014 Feb;30(2):94–100.
- Pedersen IB, Ivarsen A, Hjortdal J. Three-Year Results of Small Incision Lenticule Extraction for High Myopia: Refractive Outcomes and Aberrations. J Refract Surg. 2015 Nov;31(11):719–24.
- Beck RW, Moke PS, Turpin AH, Ferris FL 3rd, SanGiovanni JP, Johnson CA, et al. A computerized method of visual acuity testing: adaptation of the early treatment of diabetic retinopathy study testing protocol. Am J Ophthalmol. 2003 Feb;135(2):194–205.
- Nanavaty MA, Spalton DJ, Boyce J, Saha S, Marshall J. Wavefront aberrations, depth of focus, and contrast sensitivity with aspheric and spherical intraocular lenses: fellow-eye study. J Cataract Refract Surg. 2009 Apr;35(4):663–71.
- Cheng X, Bradley A, Thibos LN. Predicting subjective judgment of best focus with objective image quality metrics. J Vis. 2004 Apr;4(4):310–21.
- Guirao A, Williams DR, Cox IG. Effect of rotation and translation on the expected benefit of an ideal method to correct the eye’s higher-order aberrations. J Opt Soc Am A Opt Image Sci Vis. 2001 May;18(5):1003–15.
- Lee SB, Hwang BS, Lee J. Effects of decentration of photorefractive keratectomy on the induction of higher order wavefront aberrations. J Refract Surg. 2010 Oct;26(10):731–43.
Article / Publication Details
Received: July 22, 2019
Accepted: October 22, 2019
Published online: December 05, 2019
Issue release date: July 2020
Number of Print Pages: 7
Number of Figures: 5
Number of Tables: 2
ISSN: 0030-3747 (Print)
eISSN: 1423-0259 (Online)
For additional information: https://www.karger.com/ORE
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

Get Permission